Anteris Technologies Global Corp. (NASDAQ:AVR) announced positive one-year clinical results for its investigational DurAVR Transcatheter Heart Valve (THV), reporting a 1% heart failure hospitalization rate among 100 patients with severe aortic stenosis and small aortic annuli.
The findings were presented by Rishi Puri, MD, PhD, of Cleveland Clinic at the PCR London Valves conference on November 22, 2026.
The analysis combined patient data from the EMBARK and early feasibility studies conducted in the United States and Europe, evaluating the valve’s performance and clinical outcomes over a 12-month period.
According to Anteris, the results demonstrated sustained improvements in blood flow through the aortic valve, a low incidence of heart failure hospitalization and improvements in patients’ functional status.
The company is continuing clinical development of DurAVR through its pivotal PARADIGM trial, which will compare the investigational device directly with commercially available transcatheter aortic valve replacement (TAVR) systems.
The one-year results showed that DurAVR maintained improvements in key measures of aortic valve function.
Mean pressure gradient, which measures resistance to blood flow across the valve, declined from 48.1 mmHg before treatment to 8.9 mmHg at one year.
The mean effective orifice area, an indicator of the opening available for blood flow, increased from 0.8 cm² at baseline to 2.2 cm² after 12 months.
These findings indicate that the device maintained improved blood flow characteristics throughout the follow-up period.
Anteris also reported no cases of moderate or severe paravalvular leak, a complication in which blood flows around rather than through an implanted replacement valve.
No valve-related deaths were recorded during the one-year assessment period.
At 30 days following implantation, 97% of patients were free from moderate or severe prosthesis-patient mismatch, a condition in which the effective opening of an implanted valve is too small relative to the patient’s needs.
The company highlighted these findings as evidence of the device’s haemodynamic performance in patients with small aortic annuli, a population that can present additional challenges for valve replacement procedures.
One of the principal findings was a 1% heart failure hospitalization rate during the first year following DurAVR implantation.
Anteris compared this outcome with previously reported results from other transcatheter valve studies.
According to the company, a pooled analysis of the PARTNER trials reported a one-year heart failure hospitalization rate exceeding 6%.
In the SMART trial involving patients with small aortic annuli, the corresponding rates were 4.1% for Evolut valves and 3.5% for Sapien valves.
Although these figures provide context for the DurAVR results, they originate from separate clinical studies and do not represent a randomized, head-to-head comparison.
Differences in patient characteristics, trial designs and clinical management may influence outcomes across studies.
Anteris is pursuing a direct comparison through its ongoing PARADIGM clinical trial.
The pooled analysis included patients with substantial clinical impairment before undergoing valve replacement.
At baseline, 61% of participants were classified as New York Heart Association (NYHA) class III or IV, indicating marked limitations in physical activity or symptoms occurring at rest.
The study population also had a mean Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score of 4.7%.
Following DurAVR implantation, the proportion of patients classified as NYHA class I or II increased from 39% at baseline to 96% at one year.
NYHA class I and II classifications indicate no limitation or relatively mild limitation of physical activity.
The improvement suggests that a substantial proportion of patients experienced reduced symptom severity during the follow-up period.
The company also reported several additional clinical outcomes at one year.
All-cause mortality was 6%, while the stroke rate was 3%.
New permanent pacemaker implantation was reported in 9% of patients.
These results provide further information about the clinical experience with DurAVR in the evaluated patient population.
Anteris also presented findings from a cardiac magnetic resonance imaging substudy involving 64 patients.
The analysis showed a 24% reduction in left ventricular mass at one year following DurAVR implantation.
Left ventricular mass can increase when the heart must work harder to pump blood through a narrowed aortic valve.
A reduction following valve replacement may indicate reverse remodelling of the heart as the obstruction to blood flow is relieved.
The MRI findings therefore provide additional evidence of changes in cardiac structure following treatment.
However, the substudy involved a smaller group of patients than the overall pooled analysis, and the findings will require consideration alongside broader clinical outcomes.
Anteris is currently enrolling patients in its pivotal PARADIGM clinical trial, registered as NCT07194265.
The randomized study is designed to compare DurAVR directly with commercially available transcatheter aortic valve replacement devices.
Patient enrolment is taking place across clinical centres in the United States and Europe.
The trial’s primary composite endpoint will evaluate all-cause mortality, all stroke and cardiovascular hospitalization at one year.
By comparing DurAVR with existing treatment options within the same clinical trial, PARADIGM is intended to provide more direct evidence of the investigational valve’s relative clinical performance.
The study will be an important part of Anteris’ efforts to establish the safety and effectiveness of DurAVR and support its future regulatory strategy.
The company has not provided a revised commercial launch timetable in connection with the latest results.
Despite the encouraging one-year findings, DurAVR remains an investigational medical device and has not received approval for commercial sale.
The pooled results from EMBARK and the early feasibility studies provide additional clinical evidence regarding the device’s performance in patients with severe aortic stenosis and small aortic annuli.
However, the analysis involved 100 patients, and the comparisons with other valve systems were based on results from separate studies rather than a direct randomized assessment.
The ongoing PARADIGM trial is expected to provide more comprehensive comparative evidence.
For investors, the latest findings represent a clinical development milestone for Anteris Technologies as it advances DurAVR through its evaluation programme.
Future progress will depend on the results of the pivotal trial, the company’s ability to demonstrate clinical benefits and the outcome of subsequent regulatory reviews.
Anteris Technologies Global Corp stock price
| Nov-23 | |
| Nov-22 | |
| Nov-22 | |
| Nov-22 | |
| Nov-16 | |
| Nov-10 | |
| Nov-10 | |
| Nov-01 | |
| Nov-01 | |
| Nov-01 | |
| Oct-27 | |
| Oct-19 | |
| Oct-19 | |
| Oct-07 | |
| Sep-06 |
Join thousands of traders who make more informed decisions with our premium features. Real-time quotes, advanced visualizations, alerts, and much more.
Learn more about Finviz Elite